'Passive House'
Key points
- ‘Passive House’ is a design standard that achieves thermal comfort with minimal heating and cooling by using insulation, airtightness, appropriate window and door design, ventilation systems with heat recovery, and elimination of thermal bridges.
- Originally developed in Germany in the 1990s, Passive House principles are now being used throughout the world.
- Passive House standards are performance-based: they set performance targets to be met but do not dictate specific materials or products.
- The Passive House Institute administers a certification scheme that allows a building to be called a Certified Passive House once it has met certain performance standards.
- Passive House uses many of the same principles as passive design.
Understanding Passive House
What is ‘Passive House’?
‘Passive House’, or passivhaus as it is known in German, is a design standard that delivers healthy, comfortable and efficient buildings.
A Passive House takes a ‘fabric first’ approach. The focus of the design is ensuring the thermal envelope (the layer that separates inside from outside) is optimised to provide comfortable, healthy, indoor conditions.
The definition of a Certified Passive House is:
… a building, for which thermal comfort (ISO 7730) can be achieved solely by post-heating or post-cooling of the fresh air mass, which is required to achieve sufficient indoor air quality conditions, without the need for additional recirculation of air.
Passivhaus Institut (PHI)
As air is a poor carrier of heat energy, the heating and cooling energy requirements of the building must be very low because there is not sufficient air flow to deliver large amounts of heating or cooling energy.
A Passive House is appropriately insulated, airtight, has quality windows and reliable ventilation systems with heat recovery. A certified Passive House undergoes a quality assurance process that ensures that it is built as designed and meets the comfort standards required by the Passive House standard.
Note
Passive House is a performance-based standard: it sets parameters to be met but does not dictate how they are achieved.
Origins
The concept originated from international research into delivering comfort in homes where heating was unavailable or fuels were scarce including the Saskatchewan Conservation House in Canada in 1977 and a ‘zero energy house’ near Hanover, Germany in 1989.
The first home constructed to test the Passive House concept was completed in Darmstadt, Germany in 1991 by Dr Wolfgang Feist and Dr Bo Adamson. It has been continuously occupied by Dr Feist and his family ever since and data monitoring and testing show that the building still performs as predicted after nearly 30 years. Dr Feist established the Passive House Institute (PHI) in 1996 as an independent research institute.
Photo: PassiveHouse BB
The passive house standard and certification
The Passive House standard defines globally consistent performance metrics for buildings. The PHI administers a certification scheme that allows a building to be called a Certified Passive House. To obtain certification, a building must meet the following criteria:
- Thermal comfort must be achieved during winter (20°C minimum) as well as in summer (this can be adjusted in extreme climates), with not more than 10% of the hours in a given year over 25°C.
- Heating demand 15kWh/m2/yr or heating load 10W/m2.
- Cooling demand 15kWh/m2/yr (in humid climates this allowance increases to allow for dehumidification) or cooling load 10W/m2 (if installed)
- Humidity must not exceed 12g/kg for more than 20% of the year (~60%RH at 25°C).
- Airtightness must be 0.6ACH50 or lower and be verified on site.
- Overall energy use (Primary energy renewable must not exceed 60kwh/m2/yr. When calculating overall energy use, Passive House includes whole-of-building energy; this includes heating and cooling, hot water, lighting, fixed appliances and an allowance for consumer electronics.
PER is the amount of renewable energy required to operate the building. It is based on how much energy must be generated and includes allowances for transmission losses and seasonal storage (for example, if your renewable energy is mostly generated in summer but you need more energy in winter, allowances must be made for the storage losses associated with seasonal storage - that is, conversion to methane and back again).
The certification is carried out by a PHI-approved Passive House Certifier, and there are certifiers working throughout the world. The certification process is usually undertaken in 3 stages: a preconstruction check of documentation and modelling, evidence of construction during the build, and a post-construction blower door test.
Source: Passive House Institute. Note: The Certified Passive House graphic is only used by Your Home in the context of describing Passive House certification and quality assurance.
There are 3 levels of Passive House certification available: classic, plus, and premium. Classic does not require the installation of renewable energy generation. Passive House Plus buildings are more efficient (maximum PER of 45kWh/m2a) and will produce about as much energy as they consume over a year. Passive House Premium certified buildings are more efficient again (maximum PER of 30kWh/m2a) and will produce a significant excess of energy over the year.
Photo: Passive House Institute
Although Passive House principles are often used in new homes, buildings can be retrofitted to a Passive House standard. EnerPHit is the Passive House certification system for retrofits and renovations. It uses the same principles and processes as Passive House with slightly less stringent metrics because of the practical challenges of achieving high performance in existing buildings.
Source: Passive House Institute. Note: The EnerPHit graphic is only used by Your Home in the context of describing Passive House certification and quality assurance.
Passive House as a rating tool
The Passive House standard uses its own calculation methods, and therefore can be difficult to directly compare with other rating tools. For example, a Passive House assessment does not directly correlate to the Nationwide House Energy Rating Scheme (NatHERS) star ratings. Research undertaken by the PHI has shown that a Certified Passive House generally achieves a 50 to 90% reduction in energy demand compared with local minimum building-code-compliant buildings in Europe, North America and China. A similar analysis has not yet been undertaken in Australia.
PHI has developed thermal modelling software which uses climate data to calculate monthly heating and cooling demands and the overall energy consumption (PER). The Passive House Planning Package (PHPP) is open-source software that has a high correlation between its prediction and the real-world performance of buildings. The software can be used to compare performance results between alternative scenarios and, if cost data are available, to calculate financial metrics to estimate cost benefit. The SketchUp extension, designPH, also allows 3D modelling and a PHPP interface.
The PHPP has been developed in conjunction with dynamic simulation and performance testing and verified against the standard ASHRAE 140. This globally recognised standard (Standard Method of Test for Building Energy Simulation Computer Programs) ensures that all validated software delivers comparable results so as to give confidence to industry that the software is appropriate for use.
The PHPP uses climate data collated by the Passive House Institute from national observation organisations (for example, the Bureau of Meteorology). It is reviewed periodically and updated as needed. There are also climate data files available with future climate predictions enabling a design to be tested for future-proofing.
Passive House in Australia
The Passive House concept initially met some resistance in Australia because some people believed that it was only suited to a cold northern European climate. This idea was dispelled by the rapid uptake of Passive House ideas in China, where entire precincts are being built to Passive House standard in all climates, from cold to hot and humid.
As Australian homes are becoming increasingly well insulated and airtight, some design and construction professionals are using Passive House as an integrated, physics-based approach to ensure their buildings perform as predicted and avoid air quality and mould problems.
In 2019, the Australian Passive House Association reported 240 projects under way totalling nearly 1,200 dwellings across the country. There are 25 Certified Passive Houses in Australia, including a 152-bed student accommodation building at Monash University, Melbourne and an 11-unit apartment building in Redfern, Sydney.
Photo: Peter Clarke
Achieving Passive House
A Passive House is designed to maintain a comfortable indoor air temperature, which is defined as being between 20°C and 25°C. There is also a requirement for all internal surfaces to remain warm enough to prevent radiant asymmetry (differences between air temperatures and surface temperatures) and avoid risk of mould and condensation.
Many of the principles of Passive House are common to passive solar design, though with some key exceptions. A Certified Passive House must have:
- appropriate levels of thermal insulation
- a design that reduces thermal bridges
- airtightness
- high-performance windows and doors
- mechanical ventilation with heat recovery.
Source: Passive House Institute
Thermal insulation
Appropriate levels of insulation are required to control heat loss and gain. Depending on the location in Australia, the amount of insulation needed to meet the Passive House standard may be similar to the National Construction Code, or only slightly greater, for a similar building.
Insulation should be continuous around the building. In many Australian climates this includes needing insulation under a concrete slab and always at the perimeter.
Design to reduce thermal bridges
Thermal bridges are points where heat and cold can cross from the inside to outside (or vice versa) through floor, walls and roof components. Thermal bridges cause cold spots inside buildings in winter. Warm, moist, internal air meeting a sufficiently cold surface will also form condensation. Cold and damp conditions substantially increase the risk of mould.
In a Passive House this conduction needs to be eliminated or, as a minimum, calculated and ameliorated so it does not cause condensation, mould or excessive heat loss and gain.
Common construction materials with high conductivity that are most likely to create large thermal bridges include aluminium, steel and concrete. Common locations for thermal bridges include aluminium (non-thermally-broken) framed windows, steel beams projecting from inside to outside and uninsulated concrete slab edges.
A Passive House must be free of thermal bridges. The National Construction Code does not currently require thermal bridges to be reduced or quantified.
Photo: Envirotecture
Airtightness
A Passive House must be airtight to control water vapour transfer and the internal air quality. This prevents uncontrolled infiltration through the walls, roof and floor, which can draw pollutants into the building and cause moisture damage. There are various strategies and materials available to achieve airtightness, including orientated strand board (OSB3), plywood and specialised membranes.
Airtightness is measured using a blower door test. A fan is placed inside an adjustable door in an external opening in the building, the fan pressurises and depressurises the building to at least 50Pa of pressure difference. This equates to a 32km/h wind blowing on the building. The air volume passing through the fan is used to calculate the leakage of the building; the result is given as air changes per hour at 50Pascals (ACH50).
As mentioned earlier, the maximum permissible air leakage is 0.6ACH50; the average new Australian home is 15.4ACH50. Before starting construction, it is critical to design and document how a building will achieve the air tightness requirements for a Certified Passive House.
Photo: Wikimedia (Ket555)
Windows and doors
As part of the airtightness standard, a Passive House must have high-performance windows and doors. These must also be sized and placed carefully, with appropriate shading, to control the amount of solar heat gain in winter while reducing unwanted heat gain in summer.
The windows must be very well sealed and double or triple glazed, depending on the climate. The use of double or triple glazing reduces the heat flow outwards in winter and inwards in summer by a factor of up to 6, compared with single glazing. It also reduces the risk of condensation forming on the inside of the glass. Window frames must reduce heat transfer from inside to outside.
Because they are often sourced from overseas or use European technology, appropriate windows are often ‘tilt and turn’ and large doors use a ‘lift and slide’ mechanism to ensure they are airtight when closed. While the building is required to be airtight, openable windows are still required in a certified Passive House.
Adequate ventilation
Because a Passive House is airtight, ventilation strategies must be included to deliver fresh air for occupants. Passive House buildings may be naturally ventilated; however, Passive House buildings use a simple, mechanical ventilation system with heat recovery.
Natural ventilation requires regular occupant intervention, including overnight, if appropriate internal carbon dioxide levels are to be maintained. In most climates, opening windows to bring in outdoor air will result in less comfortable temperatures for a substantial portion of the year (for example, winter night times, summer daytimes).
Natural ventilation can also be unreliable because of naturally occurring factors: the wind may not blow when needed, or the outdoor temperature may not decrease sufficiently overnight in summer to provide night-time cooling.
A mechanical ventilation system is a very simple and low-energy setup, with fans that drive air across a heat exchanger. The heat exchanger transfers the heat energy of outgoing air to the incoming air, ensuring that the outdoor air enters the building at approximately the same temperature as the outgoing air. In winter, this pre-heats the incoming air; in summer, heat is rejected back to the outdoors.
Centralised, ducted systems are most appropriate and efficient in most cases, but a large range of solutions exist, including for retrofits.
In humid climates, an energy recovery ventilation unit may be used. Energy recovery ventilation (ERV) recovers both heat and humidity from the outgoing air. In a humid climate where a dehumidifier is used, this enables the home to maintain lower humidity levels than outdoors. In cold, low humidity climates, an ERV retains relatively higher humidity inside to prevent the internal air becoming too dry.
References and additional reading
- Australian Passive House Association.
- Passivhaus Institut, Passipedia.
- Passivhaus Institut.
- Truong H and Garvie AM (2017). Chifley passive house: a case study in energy efficiency and comfort, Energy Procedia 121:214–221.
Learn more
- Read Design for climate to explore the basic principles of passive design
- Explore Ventilation and airtightness to find ways to ensure adequate ventilation while blocking draughts and air leaks
- Look at Passive heating and Passive cooling for ways to reduce your need for heating and cooling
Authors
Principal author: Andy Marlow 2020